Free Online qPCR Analysis Tool: Import to Report, 2^-ddCt and Pfaffl, Statistics, QC, One-Click Report

Drop your qPCR export here

CSV, TSV, or TXT files. We find the results table in QuantStudio, StepOne, 7500, Bio-Rad CFX, LightCycler, Rotor-Gene, Stratagene, AriaMx and generic exports. Files without a target column need the target named in the next step.

Download blank template

Excel .xlsx / .xls files are not supported yet. Please save your workbook as CSV or TSV.

Or paste your data

About this tool

Free online qPCR analysis (ΔΔCt and Pfaffl)

Drop in the export from your qPCR instrument and a six-step wizard takes you from raw Ct values to fold change, statistics, a figure, and a methods paragraph you can paste into your paper. No spreadsheet formulas, no login, and your data stays in your browser.

How to analyze qPCR data in six steps

  1. ImportDrop a CSV, TSV, or TXT export, paste your data, or load the demo. A blank template is available.
  2. ConfirmCheck the detected instrument and map the Sample, Target, Ct/Cq, and optional Group columns.
  3. DefinePick reference genes (several are combined as a geometric mean), the calibrator group or sample, sample groups, replicate and undetermined handling, and Livak or Pfaffl.
  4. QCReview the flags, such as undetermined wells, outlier replicates, or replicates whose Ct SD is over your limit. Dismiss a flag, or go back and change your settings.
  5. ResultsSee fold change as a figure and a full table, plus the test results. Export PNG, SVG, or CSV, or copy the figure.
  6. ReportDownload an HTML report, print it or save it as PDF, or copy a paste-ready methods paragraph.

Supported instruments and files

  • Applied Biosystems QuantStudioAuto-detected
  • Bio-Rad CFXAuto-detected
  • Roche LightCyclerAuto-detected
  • Qiagen Rotor-GeneAuto-detected
  • Any other instrumentGeneric CSV or TSV, or the blank template

Excel .xlsx and .xls files aren't supported yet, so save your workbook as CSV or TSV first. No special export setting is needed: export the results table as CSV or text, and the tool skips the instrument's header lines on its own. It needs a Ct, Cq, or Cp column and a sample name column.

Input format

One row per well. The wizard detects the columns from the header names, and you can change Sample, Target, Ct/Cq, and Group on the Confirm step. Wells marked Undetermined or No Ct are flagged for QC.

ColumnExampleRequired
SampleControl_1Yes
Target / GeneGAPDHYes
Ct / Cq18.015Yes
GroupControlOptional. Otherwise taken from the start of each sample name, and you can edit it
WellA1Optional, for reference only

How the calculation works

ΔCt is the target's Ct minus the reference Ct. With several reference genes, their Ct values are averaged, which is the same as a geometric mean of their expression. ΔΔCt compares each sample's ΔCt with the mean ΔCt of the calibrator, which is a group or a single sample. Fold change is 2−ΔΔCt, so 1 means no change and 2 means double. The Livak method assumes 100% amplification efficiency. Pfaffl corrects for the efficiency of each primer pair. To use it, choose Pfaffl on the Define step and enter each target's efficiency as a percentage, where 100% means perfect doubling.

Technical replicates are averaged (mean or median). Replicates whose Ct SD goes over your limit (0.5 by default) are flagged. Undetermined wells can be flagged and left out, set to a Ct value, or excluded. Each pair of groups is compared with Welch's t-test on the log2 fold changes. The p-values are adjusted with the Holm method within each target gene, and the raw p-values stay in the tables and the CSV.

Sample methods text

Relative gene expression was quantified by qPCR. Technical-replicate Ct values were averaged (mean) per (sample, target) pair and normalized to GAPDH to obtain ΔCt. Relative quantification used the 2^-ΔΔCt (Livak) method with group "Control" as calibrator. Undetermined wells were flagged and excluded from the calculation. Bars show the geometric mean fold change of each group (6 biological replicates per group). Error bars show 95% confidence intervals computed on the log2 scale with the t distribution and back-transformed, so they are asymmetric. Groups were compared with Welch's t-test on per-sample log2 fold changes, with p-values adjusted by the Holm method within each target. Significance markers (Holm-adjusted p): ns p ≥ 0.05, * p < 0.05, ** p < 0.01, *** p < 0.001, **** p < 0.0001.

This is what the Report step writes for the demo data. It writes the paragraph for your own settings.

How to cite

EuropaDX qPCR Analysis Tool. 2026. EuropaDX, Inc. https://europadx.com/tools/qpcr/

Your data stays yours. Files are read on your own computer and never uploaded to EuropaDX.

Need more?

OmicsCloud runs the full analysis from raw files, keeps every step traceable, and shares results as an interactive study.